VLT® Sine-wave Filter MCC 101 output filters are differential mode low-pass filters that suppress the switching frequency component from the drive and smooth out the phase-to-phase output voltage of the drive to become sinusoidal. This reduces the motor insulation stress and bearing currents.

By supplying the motor with a sinusoidal voltage waveform, the switching acoustic noise from the motor is also eliminated.

 

Thermal losses and bearing currents

The sinusoidal voltage supply to the motor reduces hysteresis thermal losses in the motor. Since the motor insulation lifetime is dependent on the motor temperature, the sine-wave filter prolongs the lifetime of the motor.

The sinusoidal motor terminal voltage from the sine-wave filter furthermore has the advantage of suppressing bearing currents in the motor. This reduces the risk of flashover in the motor bearings and thereby also contributes to extended motor lifetime and increased service intervals.

Quality and design

All filters are designed and tested for operation with the VLT® AutomationDrive FC 302, VLT® AQUA Drive FC 202, and the VLT® HVAC Drive FC 102. They are rated for the nominal switching frequency of the FC series and therefore no derating of the drive is needed. The enclosure is designed to match the look and quality of the FC series drives.

Advantages

Compatible with all control principles including flux and VVC+
Parallel filter installation is possible for applications in the high power range

Range

3 x 200 – 500 V, 2.5 – 800 A
3 x 525 – 690 V, 4.5 – 660 A

Enclosures

IP00 and IP20 wall-mounted enclosures rated up to 75 A (500 V) or 45 A (690 V)
IP23 floor-mounted enclosures rated 115 A (500 V) or 76 A (690 V) or more

Optimised harmonic performance for VLT® frequency converters rated up to 250 kW.

The VLT® Advanced Harmonic Filter has been specially designed to match the Danfoss frequency converters for unmatched performance and design.

Compared to traditional harmonic trap filters, the VLT® Advanced Harmonic Filter offers a smaller foot print and higher harmonic reduction

The filter is available in two variants, AHF 005 and AHF 010. When connected at the input to a Danfoss VLT® frequency converter, the harmonic current distortion generated back to the mains is reduced to 5% or 10% Total Harmonic Current Distortion (THiD) at full load.

With effi ciency exceeding 98 % the passive filters AHF 005 and AHF 010 offer cost-effective and very robust harmonic solutions specifically for power ranges up to 250 kW.

As stand-alone options the advanced harmonic filters feature a compact housing that is easily integrated into existing panel space. This makes them well-suited for retrofi t applications with limited adjustments of the frequency converter.

Power range:

380 – 415 V AC (50 and 60 Hz
440 – 480 V AC (60 Hz)
600 V AC (60 Hz)
500 – 690 V AC (50 Hz)

Enclosure ratings:

IP20 (An IP21/NEMA 1 upgrade kit is available)
IP00 (Forced cooling is required. There is no fan in the IP00 unit. Separate cooling measures must be implemented in the cabinet as part of the installation)