<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>SINEXCEL Active Filters Greece &amp; Cyprus - drivetech.gr</title>
	<atom:link href="https://www.drivetech.gr/products/sinexcel-active-filters/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.drivetech.gr/products/sinexcel-active-filters/</link>
	<description>Drivetech - Frequency converters / Inverters &#38; soft starters</description>
	<lastBuildDate>Fri, 01 Oct 2021 07:11:42 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.2.2</generator>
	<item>
		<title>SINEXCEL Active Harmonic Filter</title>
		<link>https://www.drivetech.gr/products/sinexcel-active-filters/sinexcel-active-harmonic-filter/</link>
		
		<dc:creator><![CDATA[eL.Admin]]></dc:creator>
		<pubDate>Fri, 24 Sep 2021 11:14:55 +0000</pubDate>
				<category><![CDATA[SINEXCEL Active Filters]]></category>
		<guid isPermaLink="false">https://www.drivetech.gr/?p=1114</guid>

					<description><![CDATA[<p>Sinexcel Active Harmonic Filter can realize 2nd to 50th harmonic compensation, compensation ratio can be set...</p>
<p>The post <a rel="nofollow" href="https://www.drivetech.gr/products/sinexcel-active-filters/sinexcel-active-harmonic-filter/">SINEXCEL Active Harmonic Filter</a> appeared first on <a rel="nofollow" href="https://www.drivetech.gr">drivetech.gr</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><img decoding="async" class="aligncenter size-full wp-image-1115" src="https://www.drivetech.gr/cms/wp-content/uploads/sinexcel-active-filter.jpg" alt="" width="700" height="350" srcset="https://www.drivetech.gr/cms/wp-content/uploads/sinexcel-active-filter.jpg 700w, https://www.drivetech.gr/cms/wp-content/uploads/sinexcel-active-filter-560x280.jpg 560w" sizes="(max-width: 700px) 100vw, 700px" /></p>
<h3>1. Working principle</h3>
<p><img decoding="async" loading="lazy" class="aligncenter size-full wp-image-1186" src="https://www.drivetech.gr/cms/wp-content/uploads/working-principle.jpg" alt="" width="600" height="326" srcset="https://www.drivetech.gr/cms/wp-content/uploads/working-principle.jpg 600w, https://www.drivetech.gr/cms/wp-content/uploads/working-principle-560x304.jpg 560w" sizes="(max-width: 600px) 100vw, 600px" /><br />
 External CT detects the load current, DSP tracks instruction current and calculates the harmonic content through Intelligent Fast Fourier algorithm. Then DSP sends PWM signal to IGBT driving board which can control IGBT turning on and off to generate opposite phase of compensation harmonic current. At the same time CT detects the output current and compensation result is fed back to DSP, then the next round of logic control is carried out to realize stable power grid.</p>
<h3>2. Advantage</h3>
<p><strong>Three level topology (less switching loss &amp; higher switching frequency)</p>
<p> <img decoding="async" loading="lazy" class="aligncenter size-full wp-image-1125" src="https://www.drivetech.gr/cms/wp-content/uploads/active-harmonic-2.jpg" alt="" width="982" height="294" srcset="https://www.drivetech.gr/cms/wp-content/uploads/active-harmonic-2.jpg 982w, https://www.drivetech.gr/cms/wp-content/uploads/active-harmonic-2-560x168.jpg 560w, https://www.drivetech.gr/cms/wp-content/uploads/active-harmonic-2-768x230.jpg 768w" sizes="(max-width: 982px) 100vw, 982px" /><br />
 </strong></p>
<p>Compared to two-level topology, Sinexcel AHF adopts three-level topology which has twice the IGBT modules guarantees 35kHz switching frequency, and with two IGBT in each bridge arm to share the DC bus voltage instead of one, the switching losses is reduced. And three-level inverter uses multiple levels to synthesize stepped waves to approximate the sinusoidal output voltage. As there is one more output level than a two-level inverter, its output PWM wave is closer to the sinusoidal waveform with less ripple content which guarantees the output  compensation current without attenuation.</p>
<p><strong>Intelligent Fast Fourier algorithm (avoid resonance and more accurate compensation)</strong></p>
<p>Sinexcel AHF adopts Intelligent Fast Fourier algorithm instead of FFT-Fast Fourier Transform as unique intelligent FFT can automatically study system impedance, identify feature of individual harmonic order to regulate the distribution of compensation capacity, if program detects some harmonic order has resonance, it stops outputting at the order but continuous compensates the others, otherwise outputs all capacity that system needs within 5 mins. If resonance changes to the other harmonic order, the next round of self-learning is carried out to prevent system from resonance.</p>
<p><strong>Module design (small size)</p>
<p> <img decoding="async" loading="lazy" class="aligncenter size-full wp-image-1127" src="https://www.drivetech.gr/cms/wp-content/uploads/active-harmonic-3.jpg" alt="" width="400" height="320" /><br />
 </strong></p>
<p>Sinexcel AHF is in an ultra-compact design which means it can be easy installed and replaced. Wall-mounted and rack-mounted design with compact footprint make it flexible to be integrated into the system, 5 pcs modules can be put into one single cabinet with maximum capacity 750A and plug-type module can be also a choice which saves a lot space and more convenient.</p>
<h3>3. Application</h3>
<p><strong>Commercial infrastructure:</strong> hospital, railway station, airport, commercial building, theme park, wharf, IDC, etc.</p>
<p><strong>Industrial: </strong>water treatment, drilling systems, oil &amp; gas, food processing, car accessories manufacturer,power supply manufacturer, irrigation, etc.
 </p>
<h3>4. Qualifications:</h3>
<p>CCS/ DNV/ RINA/ BV, UL, C-ETL-US (UL508), CE
 </p>
<h3>Brochures</h3>
<ul>
<li><a href="https://www.drivetech.gr/cms/wp-content/uploads/AHF-Brochure.pdf" target="_blank" rel="noopener">AHF Brochure</a></li>
</ul>
<p>The post <a rel="nofollow" href="https://www.drivetech.gr/products/sinexcel-active-filters/sinexcel-active-harmonic-filter/">SINEXCEL Active Harmonic Filter</a> appeared first on <a rel="nofollow" href="https://www.drivetech.gr">drivetech.gr</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SINEXCEL Static Var Generator</title>
		<link>https://www.drivetech.gr/products/sinexcel-active-filters/sinexcel-static-var-generator/</link>
		
		<dc:creator><![CDATA[eL.Admin]]></dc:creator>
		<pubDate>Thu, 23 Sep 2021 07:38:02 +0000</pubDate>
				<category><![CDATA[SINEXCEL Active Filters]]></category>
		<guid isPermaLink="false">https://www.drivetech.gr/?p=1138</guid>

					<description><![CDATA[<p>Sinexcel SVG adopts inverter-based technology which is an active solution for power factor correction that it can...</p>
<p>The post <a rel="nofollow" href="https://www.drivetech.gr/products/sinexcel-active-filters/sinexcel-static-var-generator/">SINEXCEL Static Var Generator</a> appeared first on <a rel="nofollow" href="https://www.drivetech.gr">drivetech.gr</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>&nbsp;</p>
<p><img decoding="async" loading="lazy" class="aligncenter size-full wp-image-1140" src="https://www.drivetech.gr/cms/wp-content/uploads/svg-sinexcel.jpg" alt="" width="700" height="314" srcset="https://www.drivetech.gr/cms/wp-content/uploads/svg-sinexcel.jpg 700w, https://www.drivetech.gr/cms/wp-content/uploads/svg-sinexcel-560x251.jpg 560w" sizes="(max-width: 700px) 100vw, 700px" /></p>
<h3>1. Working principle</h3>
<p><img decoding="async" loading="lazy" class="aligncenter size-full wp-image-1186" src="https://www.drivetech.gr/cms/wp-content/uploads/working-principle.jpg" alt="" width="600" height="326" srcset="https://www.drivetech.gr/cms/wp-content/uploads/working-principle.jpg 600w, https://www.drivetech.gr/cms/wp-content/uploads/working-principle-560x304.jpg 560w" sizes="(max-width: 600px) 100vw, 600px" /><br />
 External CT detects the load current, DSP tracks instruction current and calculates the reactive power change rate through the Instantaneous Reactive Power Algorithm. Then DSP sends PWM signal to IGBT driving board which can control IGBT on and off to generate inductive or capacitive compensation current. At the same time CT detects the output current and compensation result is fed back to DSP, then the next round of logic control is carried out to realize stable power grid.</p>
<h3>2. Advantage</h3>
<p><strong>Superior performance (PFC 0.99&amp;-1~1 Compensating)<br />
 </strong>Sinexcel SVG adopts inverter-based technology which is an active solution for power factor correction that it can realize step-less compensation without over-compensation and under- compensation. PFC process with both inductive reactive power and capacitive reactive power within 15ms and maintains PF 0.99at all timesirrespective of how much or how fast the system reactive power changes,instead of cap-banks can only compensate inductive reactive power.</p>
<p><strong>High Reliability (long lifespan &amp; operate normally in 15% THDV environment)<br />
 </strong>The MTBF (mean time between failures) of Sinexcel SVG is up to 100000 hours of operation, but for capbank whose available compensating capacity is directly determined by the capacity of every single capacitor whichwill decrease over time,it needs to be monitored and replaced at regular intervals.As cap bank is a passive solution, it works by changing the system impedance which can increase resonance risk. And capacitor impedance related to current frequency, harmonic currents cause an internal breakdown of the capacitors and may result in an explosion. Instead Sinexcel SVG is not influenced by harmonicand can operate normally in 15% THDV environment due to the inverter-based technology.</p>
<p>Moreover, Sinexcel SVG can compensate the leading and lagging power factor and has tolerance on the high THDI, THDU system.  </p>
<p><strong>Module design (small size)</p>
<p> <img decoding="async" loading="lazy" class="aligncenter size-full wp-image-1143" src="https://www.drivetech.gr/cms/wp-content/uploads/sinexcel-svg-2a.jpg" alt="" width="500" height="356" /><br />
 </strong></p>
<p>Sinexcel SVG is in an ultra-compact design which makes it can be easy installed and replaced. Wall-mounted and rack-mounted design with minimal footprint make it flexible to be integrated into the system, with its high density, 5 pcs 100kvar SVG can be put into one single cabinet, more than 70% space can be savedcompared with cap banks.</p>
<h3>3. Application</h3>
<p><strong>Commercial infrastructure:</strong> hospital, railway station, airport, commercial building, theme park, wharf, IDC, etc.</p>
<p><strong>Industrial: </strong>water treatment, drilling systems, oil &amp; gas, food processing, car accessories manufacturer,power supply manufacturer, irrigation, wind farm etc.</p>
<h3>4. Qualifications<strong><br />
 </strong></h3>
<p>CCS/ DNV/ RINA/ BV, UL, C-ETL-US (UL508), CE</p>
<h3>Brochures</h3>
<ul>
<li><a href="https://www.drivetech.gr/cms/wp-content/uploads/SVG-Brochure_updated.pdf" target="_blank" rel="noopener">SVG Brochure</a></li>
</ul>
<p>The post <a rel="nofollow" href="https://www.drivetech.gr/products/sinexcel-active-filters/sinexcel-static-var-generator/">SINEXCEL Static Var Generator</a> appeared first on <a rel="nofollow" href="https://www.drivetech.gr">drivetech.gr</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SINEXCEL Advanced Static Var Generator</title>
		<link>https://www.drivetech.gr/products/sinexcel-active-filters/sinexcel-advanced-static-var-generator/</link>
		
		<dc:creator><![CDATA[eL.Admin]]></dc:creator>
		<pubDate>Wed, 22 Sep 2021 07:49:37 +0000</pubDate>
				<category><![CDATA[SINEXCEL Active Filters]]></category>
		<guid isPermaLink="false">https://www.drivetech.gr/?p=1148</guid>

					<description><![CDATA[<p>Sinexcel Advanced Static Var Generator (ASVG) conducts real-time monitoring to load current through external Current Transformer (CT)</p>
<p>The post <a rel="nofollow" href="https://www.drivetech.gr/products/sinexcel-active-filters/sinexcel-advanced-static-var-generator/">SINEXCEL Advanced Static Var Generator</a> appeared first on <a rel="nofollow" href="https://www.drivetech.gr">drivetech.gr</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><img decoding="async" loading="lazy" class="aligncenter size-full wp-image-1149" src="https://www.drivetech.gr/cms/wp-content/uploads/asvg-sinexcel.jpg" alt="" width="700" height="350" srcset="https://www.drivetech.gr/cms/wp-content/uploads/asvg-sinexcel.jpg 700w, https://www.drivetech.gr/cms/wp-content/uploads/asvg-sinexcel-560x280.jpg 560w" sizes="(max-width: 700px) 100vw, 700px" /></p>
<p>&nbsp;</p>
<h3>1. Working principle</h3>
<p><img decoding="async" loading="lazy" class="aligncenter size-full wp-image-1186" src="https://www.drivetech.gr/cms/wp-content/uploads/working-principle.jpg" alt="" width="600" height="326" srcset="https://www.drivetech.gr/cms/wp-content/uploads/working-principle.jpg 600w, https://www.drivetech.gr/cms/wp-content/uploads/working-principle-560x304.jpg 560w" sizes="(max-width: 600px) 100vw, 600px" /><br />
 Sinexcel Advanced Static Var Generator (ASVG) conducts real-time monitoring to load current through external Current Transformer (CT) and detects reactive components and harmonic from load current through the calculation of internal Digital Signal Processor (DSP) , then transmits PWM signal to internal Insulated Gate Bipolar Transistor (IGBT). Conforming reactive current and low-order harmonic current are generated by inverter with control settings to achieve reactive compensation and control harmonic.</p>
<h3>2. Advantage</h3>
<p><strong>&#8220;One-stop&#8221; General Compensation Technique</strong></p>
<p><strong>Power factor, Three-phase unbalanced and Low-order harmonic synchronization control</strong></p>
<ul>
<li>Power factor correction &amp; Three-phase balancing</li>
<li>Support low-order (3, 5, 7, 9, 11 13 orders) harmonic compensation (≤50% rated capacity)</li>
</ul>
<p><strong>Resonance avoidance</strong></p>
<ul>
<li>ASVG is a current source device which avoids resonance phenomena in mechanism.</li>
</ul>
<p><strong>Excellent harmonic characteristics</strong></p>
<ul>
<li>No harmonic is generated, no harmonic is amplified and the odd harmonic orders lower than 13th can be filtered.</li>
</ul>
<p><strong>Stepless adjustment</strong></p>
<ul>
<li>ASVG can realize dynamic stepless power factor correction without over-compensation and under-compensation.</li>
</ul>
<p><strong>Modularized product design</strong></p>
<ul>
<li>ASVG adopts modular product design and cabinet installation.</li>